Olympus INNOV-X Delta Premium DP-6000-C

Olympus Delta analysers are compact and robust, with sophisticated XRF technology that’s better, faster, and more responsive. You will immediately notice the amazing responsiveness from the probe to the trigger to the display. From initial boot-up to the final result, the Olympus Innov-X Delta Premium is the optimum solution for all your analytical needs.

The Olympus Delta line can provide you with the ultimate experience in the field with amazing portable handheld XRF analysis. Get fast measurements with accuracy, precision, detection limit, and light element measurement capabilities, all in a compact single-chassis frame, wrapped in robust industrial-grade body casing.

Product Specifications

Excitation Source: 4 watt X-ray tube with Rhodium anode, range 8-40 KeV, 5-200 µA, 8 filter positions.
Detector: Large area Silicon drift detector
Digital Pulse Processor: Floating point processor, High count rate (HCR) up to 300,000 cps.
Barometer: Built-in barometer for atmospheric pressure correction for light elements
 Power:  Li-ion batteries or AC power
 Battery life:  2-4 hours depending on external conditions and usage
 Battery change:  Battery hot swap available
 Battery Recharge:  Via Docking station, 2 batteries simultaneously
 Connectivity:  USB, Bluetooth
 Data Download:  Direct to PC in CSV format
 Weight of instrument:  1.6 Kg

Application Modes

  • Element range: From P to U.
  • Beams: 2 beams at 40 KV, 1 at 15 KV
  • Method of Calculation: Compton Normalisation
  • Recommended Beam times: 10-30 secs per beam (depending on accuracy required)
  • Units: ppm recommended (also percent).
  • Applications: Grade control, environmental soil screening, low level (<10%) elemental concentration in rock chips, core.
  • Element range: From Mg to U.
  • Beams: 1 beams at 40 KV, 1 at 10 KV
  • Method of Calculation: Fundamental Parameters
  • Recommended Beam times: 10-30 secs per beam (depending on accuracy required)
  • Units: percent recommended (also ppm).
  • Applications: Geochemical soil testing, environmental – heavily contaminated soil screening, high level (>10%) elemental concentration in rock chips, core.
  • Element range: Selected elements from Cl to Sb
  • Beams: 2 beams at 40 KV
  • Test end Conditions: Maximum time, Action level (IEC guideline or user defined), Classification
  • Recommended Beam times: 10-30 secs per beam (depending on accuracy required)
  • Units: ppm
  • Applications: RoHS/ WEE.
  • Element range: Selected elements from Mg to Sb
  • Beams: 1 beams at 40 KV, 1 beam at 13KV, 1 beam at 8KV
  • Test end Conditions: Single beam with/without LE detection, two beams always (AL, Si, Mg, S, P), Smart sort
  • Recommended Beam times: 10-30 secs per beam (depending on accuracy required)
  • Units: ppm
  • Applications: RoHS/ WEE.
  • Element range: From Mg to U.
  • Beams: 1 beams at 40 KV,
  • Method of Calculation: Fundamental Parameters
  • Recommended Beam times: 10-30 secs per beam (depending on accuracy required)
  • Units: percent recommended (also ppm).
  • Applications: Grade control.
  • Element range: From Mg to U.
  • Beams: 1 beam at 40 KV, 1 beam at 10 KV
  • Method of Calculation: Fundamental Parameters
  • Recommended Beam times: 10-30 secs per beam (depending on accuracy required)
  • Units: ppm and percent
  • Applications: Geochemical soil analysis from ppm to percent.
  • Element range: Pb.
  • Beams: 1 beam at 40 KV, 1 beam at 10 KV
  • Test end Conditions: Inspection, fixed time.
  • Recommended Beam times: 10-30 secs per beam (depending on accuracy required)
  • Units: mg Pb /cm2 paint
  • Applications: Lead paint analysis.
Enquire Now